Three Phrase 10KW On Grid/Off Grid Solar Hybrid Inverter with Parallel Function MPPT Controller

1.Pure sine wave output

2. Self-consumption and deed in to the grid

3. Programmable supply priority for PV,Battery or Grid

4. User-adjustable battery charging current suits different types of batteries

5. Programmable multiple operation modes: Grid-tie,Off-grid and grid-tie with backup

6. Built-in timer for various mode of on/off operation

7. Multiple communication for USB,RS232,Modbus and SNMP

8. Monitoring software for rel-time status display and control


Description

Description

Features:

1. Pure sine wave output
2. Self-consumption and deed in to the grid
3. Programmable supply priority for PV,Battery or Grid
4. User-adjustable battery charging current suits different types of batteries
5. Programmable multiple operation modes: Grid-tie,Off-grid and grid-tie with backup
6. Built-in timer for various mode of on/off operation
7. Multiple communication for USB,RS232,Modbus and SNMP
8. Monitoring software for rel-time status display and control
9. Parallel operation up to 6 units for 10KW

Model HYG5532 HYG1033
PHASE 1-phase in/1 phase out 3-phase in/3-phase out
Max. PV INPUT POWER 6500W 14850W
Rated Output Power 5500W 10000W
Maximum Charging Power 2880 W 9600 W
GRID TIE OPERATION
PV INPUT (DC)
Nominal DC Voltage/Max. DC Voltage 360 VDC/500 VDC 720 VDC/900 VDC
Start-up Voltage/Initial Feeding Voltage 116 VDC/150 VDC 320 VDC/350 VDC
MPP Voltage Range 120 VDC~450 VDC 400 VDC~800 VDC
Number of MPP Trackers/ 2/2x13A 2/2×18.6A
Maximum Input Current
GRID OUTPUT (AC)
 

Nominal Output Voltage

 

208/220/230/240 VAC

230 VAC (P-N)/
400 VAC (P-P)
Output Voltage Range 184 -265 VAC* 184 – 265 VAC* per phase
Nominal Output Current 23.9A 14.5A per phase
Power Factor > 0.99
EFFICIENCY
Maximum Conversion Efficiency (DC/AC) 96%
European Efficiency@Vnominal 95%
OFF GRID OPERATION
AC INPUT
AC start-up Voltage/  

120-140 VAC/180 VAC

120-140 VAC per phase/
Auto Restart Voltage 180 VAC per phase
Acceptable Input Voltage Range 170-280 VAC 170-280 VAC per phase
Max. AC Input Current                                           40A 40A
PV INPUT (DC)
Max. DC Voltage 500 VDC 900 VDC
MPP Voltage Range 120 VDC~450 VDC 400 VDC~800 VDC
Number of MPP Trackers/Max. Input Current 2/2x13A 2/2×18.6A
BATTERY Mode Output (AC)
Nominal Output Voltage 202/208/220/230/240 VAC 230 VAC (P-N)/400 VAC (P-P)
Output Waveform Pure Sine Wave
Efficiency (DC to AC) 93% 91%
HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage/Max. DC Voltage 360 VDC/500 VDC 720 VDC/ 900 VDC
Start-up Voltage/Initial Feeding Voltage 116 VDC/150 VDC 320 VDC/ 350 VDC
MPP Voltage Range 120 VDC~450 VDC 400 VDC~800 VDC
Number of MPP Trackers/Max. Input Current 2/2x13A 2/2×18.6A
GRID OUTOUT (AC)
 

Nominal Output Voltage

202/208/220/230/240 VAC 230 VAC (P-N)/
400 VAC (P-P)
Output Voltage Range 184-264.5 VAC* 184-264.5 VAC* per phase
Nominal Output Current 23.9A 14.5A per phase
AC INPUT
AC Start-up Voltage/Auto Restart Voltage 120-140 VAC/180 VAC 120-140 VAC per phase/

180 VAC per phase

Acceptable Input Voltage Range 170-280 VAC 170-280 VAC per phase
Max. AC Input Current 30A 40A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage  

202/208/220/230/240 VAC

230 VAC (P-N)/
400 VAC(P-P)
Efficiency (DC to AC) 93% 91%
BATTERY& CHARGER
Battery DC Voltage 48V
Max. Charging Current  

Default 60A

Default 60A, 10A-200A (Adjustable)
GENERAL
PHYSICAL
Dimension, D x W x H (mm) 110*450*445 167.5 x 500 x 622
Net weight (kgs) 16 45
INTERFACE
Communication Port RS-232/USB and CAN Interface
ENVIRONMENT
Humidity 0 ~90%RH
Operating Temperature 0 to 40°C -10 to 55 °C
Altitude 0-1000 m**

 

Solar Inverter LCD and connecting board diagram:

Monitoring Software

The solar inverter come with monitoring software can monitoring multipke devices via serial port at the same time.

It includes data log for device, alarm messages, fault messages, and parameters setting for device.

Package:

Project Cases:

Company

Product Cartification: